Messbericht über kontinuierliche Messungen von Luftschadstoffen bei Anlagen zur biologischen Behandlung von Abfällen vorlegen
Inhalt
Begriffe im Kontext
- Prüfung und Nachweise für Sachkunde und Sicherheit (2120300)
- Abfall, Schadstoffe und Emissionen (2130100)
Fachlich freigegeben am
Fachlich freigegeben durch
- § Section 26 of the Federal Immission Control Act (BImSchG)
- § Section 29 of the Federal Immission Control Act (BImSchG)
- § 9 Ordinance on plants for the biological treatment of waste (30th BImSchV)
- Annex (to Section 1) Serial number 3.20.4 State ordinance on responsibilities in the field of immission control (ImSch-ZuVO)
- § Section 1 State Ordinance on Responsibilities in the Field of Immission Control (ImSchZuVO)
- § 2 State ordinance on responsibilities in the field of immission control (ImSchZuVO)
- § Section 7 of the Administrative Organization Reform Act (VwORG)
- § Section 8 of the Administrative Organization Reform Act (VwORG)
If you operate a biological waste treatment plant, you must continuously determine, record and evaluate the air pollutant emissions for certain air pollutants by means of continuous measurements.
If you are the operator of a biological waste treatment plant, you must continuously determine, record and evaluate the air pollutant emissions for certain air pollutants by means of continuous measurements with special measuring devices.
You must prepare a measurement report on the evaluation of the measurements and send it to the immission control authority responsible for you within certain deadlines.
- You are the operator of a plant for the biological treatment of waste.
- You have put your plant into operation.
- You evaluate the measurements.
- You create a measurement report.
- You send the measurement report to the responsible immission control authority within the prescribed period.
- You must submit the measurement report to the responsible immission control authority within 3 months of the end of each calendar year.
- You must keep the records of the measuring devices for at least 5 years after preparing the measurement report.
You can use the following website to search online for accredited measuring institutes that can certify the correct installation of the measuring devices you use:
- certify proper installation,
- carry out the calibration,
- test the functionality once a year.
You are committing an administrative offense if you:
- do not evaluate measurements, do not evaluate them correctly or do not evaluate them completely,
- do not submit the measurement report on time,
- do not keep the records of the measuring devices used for at least 5 years after the measurement report has been drawn up.
None. The administrative service is a real act against which no legal remedy is possible.
- Measurement report on continuous measurements of air pollutants Receipt at plants for the biological treatment of waste
- Operators of biological waste treatment plants must continuously determine, record and evaluate air pollutant emissions by means of continuous measurements.
- The operator must prepare a measurement report on the evaluation of the measurements and submit it to the competent authority within three months of the end of each calendar year
- Responsible: competent immission control authority
- in Rhineland-Palatinate: responsible structural and licensing directorate